a9 -30-10 a26 -30-10 a.c. control circuit supply types a12 -30-10 a30 -30-10 a16 -30-10 a40 -30-10 a.c. & control circuit supply types d.c. (electronic coil interface) ae9 -30-00 ae26 -30-00 d.c. control circuit supply types ae12 -30-00 ae30 -30-00 ae16 -30-00 ae40 -30-00 1 x n.c. 1 x n.o. ca 5-10 1-pole, front mounting ca 5-01 1-pole, front m ac-1 utilization category when making, the switched-on current is equal to the i n load rated current with cos j 3 0.95. ac-3 utilization category when making, the motor current is about 6 x i n . breaking while the motor is running at i n motor f.l.c. a.., af .., 3-pole contactors rv 5 rc 5-1 ve 5-1 vm 5-1 tp 40 da, tp 180 da direct timing - front mounting tp 40 i te5s direct timing - indep & setting range in amps auxiliary ca 5-.., 1-pole types contacts cal 5-.., 2-pole timers tp.., pneumatic types te.., electronic supply voltages: 24 v a.c./d.c., 110 ... 120; 220 ... 240; 380 ... 440 v a.c. interlocks ve 5-., mechanical / electrical types vm..., mechanical mounting between 2 contactors surge rv.., (varistor) a.c./d.c. types suppressors rc.., (capacitor) a.c. o/l relays ta..du.., thermal o/l relay types e..du.., electronic o/l relay standard starting time 2 ... 10 s tripping class 10 a selection & ordering select accessory type and quote required data in plain text.
a50 -30-00 a95 -30-00 a145 -30-11 a210 -30-11 a63 -30-00 a110 -30-00 a185 -30-11 a260 -30-11 a75 -30-00 a300 -30-11 af50 -30-00 af95 -30-00 af145 -30-11 af210 -30-11 af400 -30-11 af 580 -30-11 af63 -30-00 af110 -30-00 af185 -30-11 af260 -30-11 af 460 -30-11 af 750 -30-11 af75 -30-00 af300 -30-11 1 x n.o. + 1 x n.c. 1 x n.o. + 1 x n.c. 1 x n.o. + 1 x n.c. cal 5-11 2-pole, side mounting bar / mm vm 750h vm 300h ve 5-2 rc 5-2 the built-in coil interface eliminates the need of extra surge suppressors on these sizes rv 5 rc 5-2 te5s independent mounting te5s direct timing - independent mounting a inverse timing - front mounting ng cal 5-11 2-pole, side mounting cal 5-11 b (1 st block) (2 nd block) 100...320 e 320 du 60...200 e 200 du 250...800 e 800 du 150...500 e 500 du
abb limited 2/ 4 a 9 ... a 110 3-pole contactors a.c. operated
rated operational auxiliary contacts weight footprint order code current fitted kg h w d 1st stack ac-3 ac-1 400 v 40 ? state coil voltage a a kw (see table below) 1 - 0.34 74 44 74 a9.30.10 9 25 4 - 1 0.34 a9.30.01 1 - 0.34 74 44 74 a12.30.10 12 27 5.5 - 1 0.34 a12.30.01 1 - 0.34 74 44 74 a16.30.10 17 30 7.5 - 1 0.34 a16.30.01 1 - 0.60 90 54 94 a26.30.10 26 45 11 - 1 0.60 a26.30.01 1 - 0.71 90 54 108 a30.30.10 32 55 15 - 1 0.71 a30.30.01 1 - 0.71 90 54 108 a40.30.10 37 60 18.5 - 1 0.71 a40.30.01 50 100 22 1 1 1.20 110 82 108 a50.30.11 65 115 37 1 1 1.20 110 82 108 a63.30.11 75 125 40 1 1 1.20 110 82 108 a75.30.11 96 145 45 1 1 2.04 148 102 124 a95.30.11 110 160 55 1 1 2.04 148 102 124 a110.30.11 abb limited 2/ 5 a 9 ... a 110 3-pole contactors a.c. operated
abb limited 2/ 6
a 9 ... a 110 3-pole contactors thermal o/l relays abb limited 2/ 7
abb limited 2/ 8 a 145 ... af 750 3-pole contactors a.c. operated - a 145 ... a 300 contactors a.c. / d.c. operated - af 400 ... af 750 contactors application a 145 ... af 750 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 v a.c. or 220 v d.c. / 600 v d.c. the contactors can also be used for many other applications such as isolation, bypass, capacitor switching, lighting... description the a 145 ... af 750 3-pole contactors are of the block type design. main poles and auxiliary contact blocks 3 main poles, 1 n.o. and 1 n.c. auxiliary contact block (fitted on the left side) . a maximum of 4 auxiliary contact blocks can be fitted on each contactor. control circuit: a 145 ... a 300 contactors: a.c. operated with laminated magnet circuit, af 400 ... af 750 contactors: a.c. operated, large voltage range, with electronic coil interface, with laminated magnet circuit. contactors af 400 ... af 750 are fitted as standard with an electronic coil interface which accepts a wide control voltage range for a.c. 50/60 hz supply or d.c. supply. accessories: a wide range of accessories is available. v ariants + next pages in this section a.c./d.c. operated, large voltage range, with electronic coil interface: af 145 ... af 300 contactors. a 1 4 5 . . . a300 contactors main terminals in line with isomax circuit breakers.
a 145 ... af 750 3-pole contactors a.c. operated - a 145 ... a 300 contactors a.c. / d.c. operated - af 400 ... af 750 contactors abb limited 2/ 9
abb limited 2/ 10 a 145 ... af 750 3-pole contactors main accessories auxiliary contact blocks mounting on positioning contacts weight order code contactors kg a 145 to side 1 1 0.050 cal 5-11 af 750 1 1 0.050 cal 5-11b electronic timers for star-delta starters (dwelling time 50 ms) - (prohibited with af... contactors) mounting timing rangesupply voltage weight order code v kg independent direct 24 a.c. / d.c. 0.080 te5s-24 0.8 ... 8 s 110 ... 120 a.c. 0.080 te5s-120 or 220 ... 240 a.c. 0.080 te5s-240 6 ... 60 s 380 ... 440 a.c. 0.080 te5s-440 interlocks for two horizontal mounted contactors left right feature weight order code contactor contactor kg a 95 ... 300 a 145 ... 300 mechanical 0.150 vm 300h a 210 ... 300 af 400 ... 460 mechanical 0.150 vm 300/460h af 400 ... 750 af 400 ... 460 mechanical 0.200 vm 750h surge suppressors mounting on feature voltage range weight order code contactors kg 24 ... 50 v a.c. 0.015 rc 5-2/50 a 145 ... 300 rc 50 ... 133 v a.c. 0.015 rc 5-2/133 110 ... 250 v a.c. 0.015 rc 5-2/250 250 ... 440 v a.c. 0.015 rc 5-2/440 note: the built-in coil interface eliminates the need of extra surge suppressors on the af 400 to af 750 contactors. shrouds (terminal protection acc. to vde 0106, part 100) (pack of 2) mounting on suitable for weight order code contactors contactor with kg 1 piece a 145, a 185 cable connectors 0.100 lt 185-ac a 145, a 185 cable lugs 0.100 lt 185-al a 210 ... a 300 cable connectors 0.100 lt 300-ac a 210 ... a 300 cable lugs 0.100 lt 300-al af 400, af 460 cable connectors 0.150 lt 460-ac af 400, af 460 cable lugs 0.800 lt 460-al af 580, af 750 cable connectors 0.150 lt 750-ac af 580, af 750 cable lugs 0.850 lt 750-al other accessories a wide range of accessories are available: ?lz... connectors, ?lw... enlargement pieces for terminals, ?connecting auxiliaries: shorting bars, connection bars, additional pieces, etc. ?shrouds for shorting bars, ?interlocks for two vertical contactors, ?adapter plates. lt?al lt?ac
a 145 ... af 750 3-pole contactors thermal & electronic o/l relays abb limited 2/ 11 e 800 du e 320 du ta 450 du ta 200 du
abb limited 2/ 12 af 50 ... af 750 3-pole contactors a.c. / d.c. operated - large voltage range electronic coil interface control circuit with electronic coil interface. control inputs (af 400 ... af 750)
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 13 af 50 ... af 750 3-pole contactors a.c. / d.c. operated - large voltage range electronic coil interface rated operational auxiliary contacts footprint weight order code current fitted h w d kg ac-3 ac-1 400 v q 40 ? state coil voltage a a 50 100 1 1 110 82 108 1.220 af 50-30-11 65 115 1 1 110 82 108 1.220 af 63-30-11 75 125 1 1 110 82 108 1.220 af 75-30-11 96 145 1 1 148 102 124 2.070 af 95-30-11 110 160 1 1 148 102 124 2.070 af 110-30-11 145 250 1 1 196 112 160 3.600 af 145-30-11 185 275 1 1 196 112 160 3.600 af 185-30-11 210 350 1 1 227 140 181 6.200 af 210-30-11 260 400 1 1 227 140 181 6.200 af 260-30-11 305 500 1 1 227 140 181 6.200 af 300-30-11 400 600 1 1 278 186 216 12.00 af 400-30-11 460 700 1 1 278 186 216 12.00 af 460-30-11 580 800 1 1 283 210 242 15.00 af 580-30-11 750 1050 1 1 283 210 242 15.00 af 750-30-11 af 750-30-11 af 460-30-11 af 95-30-11 af 50-30-11
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 application ae9 ... ae 40 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 v a.c. or 220 v d.c. / 440 v d.c. description the ae... series 3-pole contactors are d.c. operated contactors. ?main poles and auxiliary contact blocks - 3 main poles, - front and side mounted add-on auxiliary contact blocks. auxiliary contacts for safety circuits page x/xx ?control circuit: laminated magnet circuit and double-winding coil fed from d.c. supply via an insertion contact mounted on the device - ae9 ... ae40: built-in lagging contact for insertion of the second winding ?accessories: a wide range of accessories are available rated operational auxiliary contacts footprint current fitted h w d order code ac-3 ac-1 400 v q 40 ? state coil voltage a a 9 25 - - 74 44 74 ae 9-30-00 12 27 - - 74 44 74 ae 12-30-00 16 30 - - 74 44 74 ae 16-30-00 26 45 - - 90 54 94 ae 26-30-00 32 55 - - 90 54 108 ae 30-30-00 37 60 - - 90 54 108 ae 40-30-00 for d.c. operation with solid magnetic circuit please consult us. for accessories see main accessories a9 - a110 page x/xx abb limited 2/ 14 ae 3-pole contactors d.c. operated with double - winding coil coil voltages: ae... voltage - u c v d.c. 12 24 42 48 50 60 75 110 125 220 240 250

www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 16 connections for star-delta starters application connections between the main poles of a star-delta starter. description these sets are made up of: ?three line contactor / delta contactor connections - upstream side. ?three connections for star and delta contactors mounting joined side by side - downstream side. ?the necessary elements to create the star point upstream of the star contactor. bed 16, bed 26 ?insulated, solid copper wires. bed 40 ?insulated, stranded solid copper wires. bed 50, bed 75 ?solid copper bars and insulated stranded copper wires. bed 95 ... bed 750 ?insulated, solid copper bars. bed kits are designed to accomodate mechanical interlock for contactors weight order code line and delta star kg a 9 a 9 a 12 a 9 0.040 bed 16 a 16 a 12 a 26 a 16 0.045 bed 26 a 30 a 26 0.070 bed 40 a 40 a 26 a 50 a 30 0.180 bed 50 a 63 a 40 a 75 a 50 0.180 bed 75 a 95 a 75 0.400 bed 95 a 110 a 95 0.500 bed 110 a 145 a 110 1.300 bed 145 a a 185 a 145 1.100 bed 185 a 210 a 185 1.500 bed 210 a 260, a 300 a 210, a 260 2.100 bed 300 af 400 / af 460 a 260 / a 300 3.500 bed 400 af 460 af 400 4.700 bed 460 af 580 af 460 / af 400 6.300 bed 580 af 750 af 580 7.700 bed 750 note: the connections provided for a... contactors can be used for the af, ae, and tae types.

www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 18 star-delta starting of three-phase asynchronous motors general when starting, the motor has to overcome the load torque and inertia of the driven machine. during this phase, current must remain within the limits acceptable by the mains. inertia, load torque and mains are commonly fixed data. although the type of starting reduces the inrush current as required, it also reduces the torque supplied by the motor. the result is a starting time that varies according to the starting process used. star-delta starting technical data when starting: ?inrush current is reduced to a third of direct starting current, ?motor torque is reduced to a third or even less of direct starting torque. transient currents are commonly read during star-delta switching. utilization during the initial starting phase ("star" connection), the resistive torque of the driven machine must remain, irrespective of speed, less than the "star" motor torque until "star-delta" switching occurs. this starting mode is therefore ideal for machines with no-load starting: ?machine-tools, ?centrifugal compressors, ?wood working machines, etc. in order to prevent a high current peak, at least 80 - 85 % of nominal speed must be reached before switching from star to delta. precautions motor nominal voltage in delta connection must be equal to that of the mains. example: a motor for 400 v star-delta starting must be designed for 400 v in "delta" connection. its usual designation is "400 v / 690 v motor". the motor must be constructed with 6 terminal windings. sequence starting is a three-stage process: 1st stage - "star" connection press the "on" button on the control circuit to close the km2 "star" contactor. the km1 "line" contactor then closes and the motor starts. countdown of programmed starting time (normally 6 to 10 s) then begins. 2nd stage - "star" to "delta" switching when the programmed starting time is over, the km2 "star" contactor opens. 3rd stage - "delta" connection a transition time (or dwelling time) of 50 ms is fixed between opening of the "star" contactor and closing of the "delta" contactor by the use of te5s timer. this prevents short circuit between "star" and "delta". note: when af... contactor types are used as delta and star contactors or an a... contactor as star contactor with an af... contactor as delta contactor, the use of a timer including a dwelling time (or transition time) e.g. te5s or similar is not necessary. a timer set for the starting duration in star connection is enough. an electrical interlock between star and delta is mandatory such as ve 5 or through auxiliary contacts. furthermore, in open transition, the current interruption may reach up to 95 ms: it shall be checked that this duration is compatible with the application i.e. mainly if the decreasing in rotation speed is acceptable during the starting phase.
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 19 connection bars for contactor and mccb connection bars for contactor and switch fuse application connections between contactors/starters and moulded case circuit breakers or switch fuses. description these connection sets are solid copper bars either isolated or protected by shrouds. connection bars between contactor and mccb vertical assembly contactors mccb weight order code kg a 145, a 185 t 3 0.150 bea 185/t3 a 145, a 185 s 3, s 4 0.150 bea 185/s3/s4 a 210 s 4 0.160 bea 210/s4 a 210 ... a 300 s 5 0.200 bea 300/s5 af 400, af 460 s 5 0.250 bea 400/s5 af 400 ... af 750 s 6 0.410 bea 750/s6 vertical assembly with control wire terminals (also suitable when using busbar kits for starter combinations) a 145, a 185 t 3 0.175 bea 185 d/t3 a 145 ... a 185 s 3, s 4 0.200 bea 185d/s3/s4 a 210 s 4 0.270 bea 210d/s4 a 210 ... a 300 s 5 0.320 bea 300d/s5 af 400, af 460 s 5 0.480 bea 400d/s5 af 400 ... af 750 s 6 0.720 bea 750d/s6 horizontal assembly (also suitable when using busbar kits for starter combinations) a 145, a 185 s 3, s 4 0.520 bea 185h/s4 a 210 s 4 0.620 bea 210h/s4 a 210, a 300 s 5 1.280 bea 300h/s5 af 400, af 460 s 5 1.310 bea 400h/s5 af 400, af 460 s 6 2.450 bea 460h/s6 af 580, af 750 s 6 4.010 bea 750h/s6 note : the bea... connection bars provided for the a 145 ... a 300 contactors can be used for the af 145 ... af 300 contactors. connection bars between contactor and switch fuse vertical assembly contactors switch fuse weight order code kg 1 piece a 185 oesa 250 0.260 a210 ... a 300 oesa 250 to 0.330 bef 185/oesa250 oesa 400 bef 300/oesa400 af 400 ... af 460 oesa 400 0.340 af 460 ... af 750 oesa 630 to 0.740 bef 460/oesa400 oesa 800 bef 750/oesa800 horizontal assembly a 145 os 160..lr 0.170 osza 15 a 145, a 185 oesa 250..lr 0.550 bef 185h/oesa250 a 210 ... a 300 oesa 250..lr to bef 300h/oesa400 oesa 400..lr af 400, af 460 oesa 400..lr 1.250 bef 460h/oesa400 note: the bef... connection bars provided for the a 145 ... a 300 contactors can be used for the af 145 ... af 300 contactors. a 300-30 contactor + mccb on top

www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 21 rc-eh 800 (varistor + rc) rc-eh 300 rv 5 rc 5-2 vh 800 vh 300 (mechanical / electrical) vh 145 (mechanical / electrical) ve 5-2 te5s direct timing - independent mounting (interpose an n.. contactor relay for ek 370 ... ek 1000) cal 16-11 2-pole, side mounting 1 x n.o. + 1 x n.c. 1 x n.o. + 1 x n.c.
abb limited 2/ 22 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 a 9 ... a 75 4-pole contactors a.c. operated rated operational auxiliary contacts footprint weight order code current fitted kg ac-1 40 ? h w d state coil voltage a 4 n.o. main poles 25 74 44 74 0.340 a 9-40-00 30 74 44 74 0.340 a 16-40-00 45 90 54 94 0.610 a 26-40-00 70 110 92 120 1.390 a 45-40-00 100 110 92 120 1.390 a 50-40-00 125 110 92 120 1.390 a 75-40-00 2 n.o. + 2 n.c. main poles 25 74 44 74 0.340 a 9-22-00 30 74 44 74 0.340 a 16-22-00 45 90 54 94 0.610 a 26-22-00 70 110 92 120 1.400 a 45-22-00 125 110 92 120 1.400 a 75-22-00 a 9-22-00 a 45-40-00 a 9-40-00

abb limited 2/ 24 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 ek 110 ... ek 1000 4-pole contactors a.c. operated rated operationa auxiliary contacts footprint weight order code current fitted kg ac-1 q 40 ? h w d state coil voltage a 200 1 1 156 165 155 4.300 ek 110-40-11 250 1 1 172 165 155 4.350 ek 150-40-11 300 1 1 198 201 172 6.600 ek 175-40-11 350 1 1 198 201 172 6.600 ek 210-40-11 550 1 1 272 270 226 17.20 ek 370-40-11 800 1 1 272 270 226 17.20 ek 550-40-11 1000 1 1 299 270 226 17.50 ek 1000-40-11 - e = 40 ... 400 hz coil with built-in rectifier. coil voltages and codes: ek 110 ... ek 1000 voltage voltage code v - 50hz v - 60hz 48 a d 110 a e 110 120 a f 220 ... 230 * a l *read 240v 60hz for 230 ... 240 a m ek 370 ... ek 1000. 380 a n 380 ... 400 440 a p 400 ... 415 a r + other voltages: page 0/1. multi-frequency coils: ek 110 ... ek 210 voltage code v - 40 ... 400hz 110 ... 120 e f 115 ... 127 e g 220 ... 230 e l 230 ... 240 e m 380 ... 400 e p 400 ... 415 e r dual frequency coils (1): ek 370 ... ek 1000 voltage voltage code v - 50hz v - 60hz 110 110 ... 120 e f 110 ... 115 115 ... 127 e g 220 220 ... 240 e l 220 ... 230 230 ... 255 e m 380 380 ... 415 e p 380 ... 400 400 ... 440 e r (1) two auxiliary contact blocks maximum per contactor, ambient temperature < 55 ? and mounting positions 2 and 6 excluded.

abb limited 2/ 26 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401
ek 110 ... ek 1000 4-pole contactors d.c. operated
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 28 contactors for capacitor switching ac-6b utilization category according to iec 60947-4-1 capacitor transient conditions in low voltage industrial installations, capacitors are mainly used for reactive energy correction (raising the power factor). when these capacitors are energized, overcurrents of high amplitude and high frequencies (3 to 15 khz) occur during the transient period (1 to 2 ms). the amplitude of these current peaks, also known as "inrush current peaks", depends on the following factors: the network inductances. the transformer power and short-circuit voltage. the type of power factor correction. there are 2 types of power factor correction: fixed or automatic. fixed power factor correction consists of inserting, in parallel on the network, a capacitor bank whose total power is provided by the assembly of capacitors of identical or different ratings. the bank is energized by a contactor that simultaneously supplies all the capacitors (a single step). the inrush current peak, in the case of fixed correction, can reach 30 times the nominal current of the capacitor bank. fixed power factor correction an automatic power factor correction system, on the other hand, consists of several capacitor banks of identical or different ratings (several steps), energized separately according to the value of the power factor to be corrected. an electronic device automatically determines the power of the steps to be energized and activates the relevant contactors. the inrush current peak, in the case of automatic correction, depends on the power of the steps already on duty, and can reach 100 times the nominal current of the step to be energized. automatic power factor correction
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 29 a... standard 3-pole contactors for capacitor switching peak cur r ent < 30 times the rms cur r ent application the a.. . and af... contactors are suited for capacitor bank switching for the peak current and power values in the table below. the kvar ratings acc. to the table below are applicable to "star" connected capacitors (less current, cable savings). the capacitors must be discharged (maximum residual voltage at terminals < 50 v) before being re-energized when the contactors are making. in these conditions, electrical durability of contactors is equal to 100 000 operating cycles. description a 12 ... a 110 3-pole contactors a 145 ... af 750 3-pole contactors selection table type powers in kvar 50/60 hz (ac - 6b) max. peak 220/240 v 380/400 v 415/440 v 500/550v 660/690 v current 40 ? 55 ? 70 ? 40 ? 55 ? 70 ? 40 ? 55 ? 70 ? 40 ? 55 ? 70 ? 40 ? 55 ? 70 ? ?(ka) a 9 a 12 7 7 6 11 11 9.5 12 12 10.5 14 14 12 19 19 16.5 0.7 a 16 7.5 7.5 6 12.5 12.5 10 14 14 10.5 15.5 15.5 12 21.5 21.5 16.5 1 a 26 11.5 11.5 9 19 19 15 20 20 16.5 23 23 19 32 32 26 1.6 a 30 13 13 11 22 22 18.5 24 24 20.5 28 28 23 38 38 32 1.9 a 40 15 15 12 26 26 20 29 29 22 35 35 25 46 46 34.5 2.1 a 50 22 22 20 38 38 34 42 42 37 48 48 42 65 65 58.5 2.3 a 63 25 25 23 43 43 39 47 47 42.5 54 54 48.5 74 74 67 2.5 a 75 28 28 24.5 48 48 41 52 52 45 60 60 51 82 82 70 2.6 a 95 35 35 33 60 60 53 63 63 58 75 75 70 80 80 75 4 a 110 40 40 35 70 70 60 75 75 65 83 83 78 90 90 85 4 a 145 50 50 42 90 90 74 93 93 80 110 110 96 110 110 110 4 a 185 60 60 45 105 105 78 115 115 85 135 135 102 135 135 135 5 a 210 75 75 57 125 125 100 135 135 110 160 160 130 160 160 160 6.5 a 260 85 85 70 140 140 130 155 155 140 180 180 165 200 200 200 8 a 300 100 100 85 160 160 150 180 180 163 210 210 196 240 240 240 8 af 400 120 120 105 200 200 185 220 220 200 260 260 241 300 300 300 10 af 460 140 140 120 230 230 215 260 260 230 325 325 300 325 325 325 10 af 580 170 170 160 270 270 260 300 300 290 350 350 340 440 440 440 12 af 750 220 220 190 390 370 332 410 410 380 490 480 435 600 600 600 12 if, in an application, the current peak is greater than the maximum peak current specified in the last column in the table, select a higher rating, refer to the ua... contactors ( + page 2/38) or add inductances ( + application guide "contactors for capacitor switching"). the capacitor bank will be protected by gg type fuses whose rating is equal to 1.5 ... 1.8 times nominal current.
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 30 ua... 3-pole contactors for capacitor switching peak cur r ent ?< 100 times the rms cur r ent
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 31 ua...-r 3-pole contactors for capacitor switching peak cur r ent ? 100 times the rms cur r ent application the ua ...-r contactors can be used in installations in which peak current far exceeds 100 times nominal rms current. the contactors are delivered complete with their damping resistors and must be used without additional inductances (+ table below). the kvar ratings acc. to the table below are applicable to "star" connected capacitors (less current, cable savings). the capacitors must be discharged (maximum residual voltage at terminals < 50 v) before being re-energized when the contactors are making. their electrical durability is 250 000 operating cycles for u e < 500 v and 100 000 operating cycles for u e 500 v.
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 32
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 33
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 34 kc... contactor relays d.c. operated with solid magnetic coil application kc... contactor relays are used for switching auxiliary circuits and control circuits.
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 35 contactor spares a.c. operated coils for a9...a300 contactors and n contactor relays for contactors weight (kg) order code a9...a16 : ua16 : ua16..-r : n 0.093 za16 a26...a40 : ua26, ua30, ua26..-r, ua30..-r 0.148 za40 a45...a75 : ua50...ua75, ua50...-r to ua75..-r; ga75 0.166 za75 a95...a110 ; ua95...ua110 0.170 za110 a145...a185 0.180 za185 a210...a300 0.400 za300 a.c./d.c. operated coils c/w electronic interface for af 45...af750 contactors for contactors weight (kg) order code af45...af75 0.170 zaf75 af95, af110 0.200 zaf110 af145...af185 0.225 zaf185 af210...af300 0.450 zaf300 af400...af460 0.525 zaf460 af580...af750 1.335 zaf750 d.c. operated coils for ae9...ae110 contactors for contactors weight (kg) order code ae9...ae16 0.093 zae16 ae26...ae40 0.148 zae40 a.c. or d.c. coils only for contactors weight (kg) order code ek110, ek150 0.360 kh210 ek175, ek210 0.440 kh300 ek370, ek550, ek1000 0.950 kh800 sets including a d.c. coil, an economy resistor and an insertion contact for contactors weight (kg) order code ek110, 150 0.450 kp210 ek175, 210 0.550 kp300 ek370, ek550, ek1000 1.060 kp800
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 36 contactor spares main contact sets for 3-pole contactors the contact sets for 3-pole contactors consist of six fixed contacts, three moving contacts, springs and the necessary screws. for contactors weight (kg) order code a/af/ae/tae 50-30 0.115 zl50 a/af/ae/tae 63-30 0.130 zl63 a/af/ae/tae 75-30 0.145 zl75 a/af/ae/tae 95-30 0.190 zl95 a/af/ae/tae 110-30 0.190 zl110 a/af 145 0.380 zl145 a/af 185 0.380 zl185 a/af 210 0.670 zl210 a/af 260 0.670 zl260 a/af 300 0.670 zl300 af 400 1.320 zl400 af 460 1.320 zl460 af 580 1.840 zl580 af 750 1.840 zl750 ua 50, ua 50-r 0.115 zlu50 ua 63, ua 63-r 0.145 zlu63 ua 75, ua 75-r 0.145 zlu75 ua 95 0.190 zlu95 ua 110 0.190 zlu110 main contact sets for 4-pole contactors the contact sets for 4-pole contactors consist of eight fixed contacts, four moving contacts, springs and the necessary screws. for contactors weight (kg) order code a/af 45-40 0.150 zlt45 a/af 50-40 0.150 zlt50 a/af 75-40 0.160 zlt75 the contact sets for 4-pole contactors consist of eight fixed contacts, four moving contacts, springs and the necessary screws. in addition, the sets include four moving arcing contacts for ek370...ek1000 contactors. for contactors weight (kg) order code ek 110 0.450 kzk110 ek 150 0.450 kzk150 ek 175 0.700 kzk175 ek 210 0.700 kzk210 ek 370 2.400 kzk370 ek 550 2.400 kzk550 ek 1000 3.000 kzk1000
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/37 mini contactors b6...b7, bc6...bc7 ordering details rated aux. current fitted contacts ac-3 ac-1 415 v < 40? footprint weight a a kw h w d kg order code screw 3 & 4 pole ac operation 1 - 58 53 47 0.18 b6.30.10 * 8.5 20 4 - 1 58 53 47 0.18 b6.30.01 * - - 58 53 47 0.18 b6.40.00 * 1 - 58 53 47 0.18 b7.30.10 * 11.5 20 5.5 - 1 58 53 47 0.18 b7.30.01 * - - 58 53 47 0.18 b7.40.00 * flat pin 3 & 4 pole ac operation 1 - 58 53 47 0.17 b6.30.10f * 8.5 20 4 - 1 58 53 47 0.17 b6.30.01f * - - 58 53 47 0.17 b6.40.00f * 1 - 58 53 47 0.17 b7.30.10f * 11.5 20 5.5 - 1 58 53 47 0.17 b7.30.01f * - - 58 53 47 0.17 b7.40.00f * soldering pin 3 pole ac operation 8.5 20 4 1 - 45 48 48 0.17 b6.30.10p * - 1 45 48 48 0.17 b6.30.01p * 11.5 20 5.5 1 - 45 48 48 0.17 b7.30.10p * - 1 45 48 48 0.17 b7.30.01p * screw 3 & 4 pole dc operation 1 - 58 53 47 0.18 bc6.30.10 * 8.5 20 4 - 1 58 53 47 0.18 bc6.30.01 * - - 58 53 47 0.18 bc6.40.00 * 1 - 58 53 47 0.18 bc7.30.10 * 11.5 20 5.5 - 1 58 53 47 0.18 bc7.30.01 * - - 58 53 47 0.18 bc7.40.00 * flat pin 3 & 4 pole dc operation 1 - 58 53 47 0.17 bc6.30.10f * 8.5 20 4 - 1 58 53 47 0.17 bc6.30.01f * - - 58 53 47 0.17 bc6.40.00f * 1 - 58 53 47 0.17 bc7.30.10f * 11.5 20 5.5 - 1 58 53 47 0.17 bc7.30.01f * - - 58 53 47 0.17 bc7.40.00f * soldering pin 3 pole dc operation 8.5 20 4 1 - 45 48 48 0.17 bc6.30.10p * - 1 45 48 48 0.17 bc6.30.01p * 11.5 20 5.5 1 - 45 48 48 0.17 bc7.30.10p * - 1 45 48 48 0.17 bc7.30.01p * *please state coil voltage/freqency when ordering b6-30-10 b6-30-10f b6-30-10p b7-30-10 b7-40-10 b7-40-10 + caf6-11
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 38 vb 7-30-01 rated aux. current fitted contacts ac-3 ac-1 415 v < 40? footprint weight a a kw h w d kg order code screw 3 pole ac operation 8.5 20 4 1 - 58 97 47 0.34 vb6.30.10 * - 1 58 97 47 0.34 vb6.30.01 * 11.5 20 5.5 1 - 58 97 47 0.34 vb7.30.10 * - 1 58 97 47 0.34 vb7.30.01 * flat pin 3 pole ac operation 8.5 20 4 1 - 58 97 47 0.34 vb6.30.10f * - 1 58 97 47 0.34 vb6.30.01f * 11.5 20 5.5 1 - 58 97 47 0.34 vb7.30.10f * - 1 58 97 47 0.34 vb7.30.01f * soldering pin 3 pole ac operation 8.5 20 4 1 - 58 97 47 0.34 vb6.30.10p * - 1 58 97 47 0.34 vb6.30.01p * 11.5 20 5.5 1 - 58 97 47 0.34 vb7.30.10p * - 1 58 97 47 0.34 vb7.30.01p * screw 3 pole dc operation 8.5 20 4 1 - 58 97 47 0.34 vbc6.30.10 * - 1 58 97 47 0.34 vbc6.30.01 * 11.5 20 5.5 1 - 58 97 47 0.34 vbc7.30.10 * - 1 58 97 47 0.34 vbc7.30.01 * flat pin 3 pole dc operation 8.5 20 4 1 - 58 97 47 0.34 vbc6.30.10f * - 1 58 97 47 0.34 vbc6.30.01f * 11.5 20 5.5 1 - 58 97 47 0.34 vbc7.30.10f * - 1 58 97 47 0.34 vbc7.30.01f * soldering pin 3 pole dc operation 8.5 20 4 1 - 58 97 47 0.34 vbc6.30.10p * - 1 58 97 47 0.34 vbc6.30.01p * 11.5 20 5.5 1 - 58 97 47 0.34 vbc7.30.10p * - 1 58 97 47 0.34 vbc7.30.01p * mini contactors vb6...vb7, vbc6...vbc7 reversing pairs * please state coil voltage/frequency when ordering
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 39 mini contactors 3 pole bc6 interface contactors rated aux. current fitted contacts ac-3 ac-1 415 v < 40? footprint weight a a kw h w d kg order code screw 3 pole dc 24v - 1.4w 8.5 20 4 1 - 58 53 47 0.17 bc6.30.10.1.4 * - 1 58 53 47 0.17 bc6.30.01.1.4 * flat pin 3 pole dc 24v - 1.4w 8.5 20 4 1 - 58 53 47 0.17 bc6.30.10.f1.4 * - 1 58 53 47 0.17 bc6.30.01.f1.4 * soldering pin 3 pole dc 24v - 1.4w 8.5 20 4 1 - 45 48 48 0.17 bc6.30.10.p1.4 * - 1 45 48 48 0.17 bc6.30.01.p1.4 * rated aux. current fitted contacts ac-3 ac-1 415 v < 40? footprint weight a a kw h w d kg order code screw 3 pole dc 17 ... 32v - 2.4w 8.5 20 4 1 - 58 53 47 0.18 bc6.30.10.2.4 * - 1 58 53 47 0.18 bc6.30.01.2.4 * flat pin 3 pole dc 17 ... 32v - 2.4w 8.5 20 4 1 - 58 53 47 0.18 bc6.30.10.f2.4 * - 1 58 53 47 0.18 bc6.30.01.f2.4 * soldering pin 3 pole dc 17 ... 32v - 2.4w 8.5 20 4 1 - 45 48 48 0.18 bc6.30.10.p2.4 * - 1 45 48 48 0.18 bc6.30.01.p2.4 * please consult us for 5.5kw version
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 40 mini relays 4 pole k6/kc6 ordering details ac operation screw connection 4 pole relay rated contact current fitted configuration ac-1 < 40? footprint weight a h w d kg order code 4 - 58 53 47 0.18 k6.40e * 20 3 1 58 53 47 0.18 k6.31z * 2 2 58 53 47 0.18 k6.22z * flat pin connection 4 pole relay 4 - 58 53 47 0.17 k6.40e-f * 20 3 1 58 53 47 0.17 k6.31z-f * 2 2 58 53 47 0.17 k6.22z-f * soldering pin connection 4 pole relay 4 - 45 48 48 0.18 k6.40e-p * 20 3 1 45 48 48 0.18 k6.31z-p * 2 2 45 48 48 0.18 k6.22z-p * dc operation screw connection 4 pole relay rated contact current fitted configuration ac-1 < 40? footprint weight a h w d kg order code 4 - 58 53 47 0.18 kc6.40e * 20 3 1 58 53 47 0.18 kc6.31z * 2 2 58 53 47 0.18 kc6.22z * flat pin connection 4 pole relay 4 - 58 53 47 0.17 kc6.40e-f * 20 3 1 58 53 47 0.17 kc6.31z-f * 2 2 58 53 47 0.17 kc6.22z-f * soldering pin 4 pole relay 4 - 45 48 48 0.17 kc6.40e-p * 20 3 1 45 48 48 0.17 kc6.31z-p * 2 2 45 48 48 0.17 kc6.22z-p * kc6-40e-p
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 41 accessories for mini contactors ordering details reversing connecting link bsm 6-30 caf6- 11m
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 42
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 43 manual motor starter type ms 116 ms 325 ms 450 ms 495 general electrical data rated insulation voltage ui to en 60947 v ac 690 690 690 690 to csa / ul / nema v ac 600 600 600 600 rated operating voltage u e up to v 690 ac/440 dc 690 ac/440 dc 690 ac/440 dc 690 ac/440 dc rated impulse strength uimp kv 6 ?/ 6 6 6 rated continuous thermal current ith a 16 25 50 100 rated operating current ie / ac 3 max. rated frequency 1) hz 50/60 rated current ranges ie a 0.1 ... 25 11 ... 50 28 ... 100 (number of ranges) (14) (7) (6) rated service short-circuit breaking capacity ics and max. permissible back-up fuses on request dc rated operating voltage in the case of series connection of 3 main circuits (wiring diagram on request) dc 1, 60 v a on request 25 50 100 dc 3, 60 v a on request 25 50 100 dc 5, 60 v a on request 25 50 100 short circuit capacity for dc-rating on request auxiliary circuits rated operating at ac 15 to 24 v ac a 6 2.5 current ie 230 v ac a 4 2 3 / 0.5 / 6 400 v ac a 3 1 1.5 / ?/ 3 1) 2) at dc 13 to24 v dc a 2 2.5 ?/ ?/ 60 v dc a 2.5 ?/ 0.15 / 110 v dc a 0.5 0.6 0.22 / ?/ 0.5 220 v dc a 0.25 0.25 0.1 / ?/ 0.25 440 v dc a 0.1 ?/ ?/ 0.1 short-circuit protection back-up fuse gl a on request 10 gl / gg 10 a am a 6 1 ) correction factors for other frequencies on request 2 ) on front side 1 changeover contact/on front side 1 no + 1 nc / at side 1 no + 1 nc, 2 no, 2 nc 3 ) other data on request
abb limited 2/ 44 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 open design, enclosure ip 20, resistant to changeable climates. quick fastening on mounting rails din en 50 022, 35 mm without auxiliary switch. setting range weight order code a...a kg ms 116 with thermal and electromagnetic trips, short-circuit-proof up to 50 ka 0.10....0.16 0.268 ms 116 - 0.16 0.16....0.25 0.268 ms 116 - 0.25 0.25....0.40 0.268 ms 116 - 0.4 0.40....0.63 0.268 ms 116 - 0.63 0.63....1.00 0.268 ms 116 - 1.0 1.00....1.60 0.268 ms 116 - 1.6 1.60....2.50 0.268 ms 116 - 2.5 2.50....4.00 0.268 ms 116 - 4 4.00....6.30 0.268 ms 116 - 6.3 6.30....10.00 0.268 ms 116 - 10.0 10.00....16.00 0.268 ms 116 - 16.0 accessories order code auxillary switches, for front-panel installation 1 no + 1 nc hkf1-11 auxiliary switches, lateral attechment at right 1 no + 1 nc hk1-11 2 no hk1-20 2 nc hk1-02 signal contakt for general ?ripped?signal, lateral attachment at right 1 no + 1 nc sk1-11 2 no sk1-20 2 nc sk1-02 undervoltage release, lateral attachment at left 24 v, 50 hz ua1-24 48 v, 50 hz ua1-48 60 v, 50 hz ua1-60 110/120 v, 50/60 hz ua1-110 208 v, 60 hz ua1-208 230 v, 50 hz ua1-230 400 v, 50 hz ua1-400 415 v, 50 hz ua1-415 manual motor starter ms 116
abb limited 2/ 45 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 1) for accommodating spindle and attachment to manual motor starter 2) is screwed directly onto the manual motor starter manual motor starter ms116 accessories description order code phase buses for cross wiring ms 116, 63 a, 690 v for 2 devices without auxiliary switches ps1-2-0 for 3 devices without auxiliary switches ps1-3-0 for 4 devices without auxiliary switches ps1-4-0 for 5 devices without auxiliary switches ps1-5-0 for 2 devices with 1 auxiliary switch ps1-2-1 for 3 devices with 1 auxiliary switch ps1-3-1 for 4 devices with 1 auxiliary switch ps1-4-1 for 5 devices with 1 auxiliary switch ps1-5-1 for 2 devices with 2 auxiliary switches ps1-2-2 for 3 devices with 2 auxiliary switches ps1-3-2 for 4 devices with 2 auxiliary switches ps1-4-2 for 5 devices with 2 auxiliary switches ps1-5-2 busbar cover bsi-3 power infeed blocks, 63 a, 690 v, stranded 25 mm2, flexible 16 mm 2 flat s1-m1 high s1-m2 mounted enclosure ip 65, triple lockable in off position, with n- und pe-terminal, metric cable gland grey enclosure with black handle ib 116-g yellow enclosure with red handle ib 116-y switch cubicle mounting kit ip 65, with axial extension triple lockable in off position, locked in on position twist knob black ohb2ajm twist knob red/yellow ohy2ajm axis 85 mm oxs5x85 axis 105 mm oxs5x105 axis 130 mm oxs5x130 axis 180 mm oxs5x180 driver 1) msmn driver spindle 32 mm 2) msox locking device lock adapter sa1 locking device assy =(adaptor sai + padlock + 3 keys) sa3 for connecting links between mms + contactor (see page x/xx)
abb limited 2/ 46 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 manual motor starter ms 325 selection open design, enclosure ip 20, resistant to changeable climates. quick fastening on mounting rails din en 50 022, 35. setting range weight order code a...a kg ms 325 with thermal and electromagnetic trips, short-circuit-proof up to 100 ka, resp.50 ka 1) 2) 0.10....0.16 0.347 ms 325 ? 0.16 0.16....0.25 0.347 ms 325 ? 0.25 0.25....0.40 0.347 ms 325 ? 0.4 0.40....0.63 0.347 ms 325 ? 0.63 0.63....1.00 0.347 ms 325 ? 1 1.00....1.60 0.347 ms 325 ? 1.6 1.60....2.50 0.347 ms 325 ? 2.5 2.50....4.00 0.347 ms 325 ? 4 4.00....6.30 0.347 ms 325 ? 6.3 6.30....9.00 0.347 ms 325 ? 9 9.00 ....12.50 0.347 ms 325 ?12.5 12.50....16.00 0.347 ms 325 ?16 16.00....20.00 0.347 ms 325 ?20 20.00....25.00 0.347 ms 325 ?25 magnetic only versions on application accessories setting range weight order code kg auxiliary switches, lateral attachment at left, max. 2 pieces attachable 1 no + 1 nc 0.031 hk-11 2 no 0.031 hk-20 2 nc 0.031 hk-02 signal contact for general ?ripped?signal, lateral attachment at the left max. 1 piece attachable 1 no + 1 nc 0.031 sk-11 locking device lock adapter 0.004 sa1 locking device assy. (adapter sa1 + padlock + 3 keys) 0.050 sa3 for other accessories please consult us. for connecting links beween mms and contactor see page ??
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 47 manual motor starters ms 4xx open design. enclosure ip 20, resistant to changeable climates. quick fastening on mounting rails din en 50 022, 35 mm without auxiliary switch setting range weight order code a . . . a kg ms 450 with thermal and electromagnetic trips, tripping class 10, short-circuit-proof up to 50 ka 11....16 0.96 ms 450 ?16 14....20 0.96 ms 450 ?20 18....25 0.96 ms 450 ?25 22....32 0.96 ms 450 ?32 28....40 0.96 ms 450 ?40 36....45 0.96 ms 450 ?45 40....50 0.96 ms 450 ?50 ms 495 with thermal and electromagnetic trips, tripping class 10, short-circuit-proof up to 50 ka 28....40 2.1 ms 495 ?40 36....50 2.1 ms 495 ?50 45....63 2.1 ms 495 ?63 57....75 2.1 ms 495 ?75 70....90 2.1 ms 495 ?90 80....100 2) 2.1 ms 495 ?100 magnetic only and heavy duty starving versions on application retrofittable accessories these parts may be procured in addition to the ms 4xx. they must be mounted by the user. type weight order code kg auxiliary switches, for front panel installation 1 no + 1nc 0.02 hk4-11 1 changeover 0.02 hk4-w auxiliary switches, for lateral attachment at left, max. 1 mountable 1 no + 1 nc 0.03 hks4-11 2 no 0.03 hks4-20 2 nc 0.03 hks4-02 pilot switch, for separate signalling of short-circuit and general tripping, lateral attachment at left, max. 1 mountable, also together with auxiliary switch for any signal 1 no + 1 nc 0.07 sk4-11 for other accessories please consult us. for connecting links beween mms and contactor see page ??
abb limited 2/ 48 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 bea 7 ... bea 110 connecting links for contactors and manual motor starters a 9-30-10 + bea 16/116 + ms 116 dol starter combination
abb limited 2/ 49 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 fbp fieldbusplug communicative motor starters - compact devices motorstarter direct msd11-fbp motor branch circuit for 1 motor, 1 direction of rotation, ip20. ?motor protection with thermal and electromagnetic trip ?compact device with fieldbus-independent interface for connection to fbp fieldbus connector ?400 v ac, max. 12 a, incl. motor connector, i cs = 10...50 ka designation setting range order code 0.16 a 0.1 - 0.16 a msd11-fbp.0.16 0.25 a 0.16 - 0.25 a msd11-fbp.0.25 0.40 a 0.25 - 0.40 a msd11-fbp.0.4 0.63 a 0.40 - 0.63 a msd11-fbp.0.63 1.0 a 0.63 - 1.0 a msd11-fbp.1 1.6 a 1.0 - 1.6 a msd11-fbp.1.6 2.5 a 1.6 - 2.5 a msd11-fbp.2.5 4.0 a 2.5 - 4.0 a msd11-fbp.4.0 6.3 a 4.0 - 6.3 a msd11-fbp.6.3 10.0 a 6.3 - 10 a msd11-fbp.10 12.0 a 8 - 12.0 a msd11-fbp.12 motorstarter direct msr22-fbp motor branch circuit for 1 motor, 2 directions of rotation, ip20. ?motor protection with thermal and electromagnetic trip ?compact device with fieldbus-independent interface for connection to fbp fieldbus connector ?400 v ac, max. 12 a, incl. motor connector, i cs = 10...50 ka designation setting range order code 0.16 a 0.1 - 0.16 a msr22-fbp.0.16 0.25 a 0.16 - 0.25 a msr22-fbp.0.25 0.40 a 0.25 - 0.40 a msr22-fbp.0.4 0.63 a 0.40 - 0.63 a msr22-fbp.0.63 1.0 a 0.63 - 1.0 a msr22-fbp.1 1.6 a 1.0 - 1.6 a msr22-fbp.1.6 2.5 a 1.6 - 2.5 a msr22-fbp.2.5 4.0 a 2.5 - 4.0 a msr22-fbp.4.0 6.3 a 4.0 - 6.3 a msr22-fbp.6.3 10.0 a 6.3 - 10 a msr22-fbp.10 12.0 a 8 - 12.0 a msr22-fbp.12 accessories for motor starters msd11-fbp and msr22-fbp busbar blocks for msd11-fbp and msr22-fbp for cross wiring. feeder block for busbar blocks msd11-fbp and msr22-fbp. ?current-carrying capacity max.63 a, connection cross-section 25/16mm 2 multipole/fine-wire designation order code busbar block for 2 devices ps1-2-0 busbar block for 3 devices ps1-3-0 busbar block for 4 devices ps1-4-0 busbar block for 5 devices ps1-5-0 feeder block, flat design s1-m1 feeder block, high s1-m2 msd11-fbp msr22-fbp
abb limited 2/ 50 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 fbp fieldbusplug communicative motor starters with control function motorstarter fieldbus interface mfi21-fbp fieldbus interface, ip20, for coupling to manual motor starter ms 325. ?integrated motor control functions - direct, reverse-start, star-delta starting, diagnostic functions ?integrated potentiometer, 3 digital inputs, 3 relay outputs, 1 direct-coupled digital input for detection of switch position of the ms 325 ?fieldbus-independent interface for connection to fbp fieldbus connector designation order code motorstarter fieldbus interface mfi21-fbp.0 *) manual motor starter ms325 and accessories for ms 325, refer to main switch and technology catalogue universal motor controller umc22-fbp universal motor controller with thermal overload protection 0.2-63a in a single device type. ?bushing-type current transformer, cable cross-section 25mm 2 ?intergrated motor control functions - direct, reverse-start, star-delta starting, servo-drive functions ?diagnostic functions - overload, phase failure, trip - trip categories 10,20,30 ?integrated storage of parameters and motor data ?6 digital inputs, 3 relay outputs ?fieldbus-independent interface for connection to fbp fieldbus connector designation rated motor current order code universal motor controller 0.2 - 63 a umc22-fbp.0 accessories for universal motor controller umc22-fbp busbar blocks for msd11-fbp and msr22-fbp for cross wiring. feeder block for busbar blocks msd11-fbp and msr22-fbp. ?current-carrying capacity max.63 a, connection cross-section 25/16mm 2 multipole/fine-wire designation order code control panel acs100-pan mfi 21 umc 22 display - umc 22
abb limited 2/ 51 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 fbp fieldbusplug communicative motor starters - compact devices (please consult us for availability of other protocol?) as-i fieldbusplug direct ready-made as-i slave fieldbus interface with various cable lengths. ?applicable on the msd11-fbp and on devices with max. 2 input signals and 1 output signal ?degree of protection ip65, diagnostic led designation cable length order code fieldbusplug as-i direct 0.25 m asd11-fbp.025 as-i direct 0.50 m asd11-fbp.050 as-i direct 1.00 m asd11-fbp.100 as-i direct 5.00 m asd11-fbp.500 as-i fieldbusplug performance ready-made as-i slave fieldbus interface with various cable lengths. ?applicable on all fbp motor starters and devices with max. 4 input signals and 3 output signals ?degree of protection ip65, diagnostic led designation cable length order code as-i performance 0.25 m asp22-fbp.025 as-i performance 0.50 m asp22-fbp.050 as-i performance 1.00 m asp22-fbp.100 as-i performance 5.00 m asp22-fbp.500 accessories for as-i bus connection as-i round cable for bus junctions ready-made bus cable with an m12 connector and an open cable end. ?application on bus junctions such e.g. as-i couplers or devices with an integrated as-i interface designation cable length order code as-i round cable 0.30 m asf11-fbp.030 with female connector as-i round cable 0.30 m asm11-fbp.030 with male connector as-i round cable for bus extension ready-made bus cable with m12 male and female connectors designation cable length order code as-i extension cable 1.00 m asx11-fbp.100 as-i extension cable 3.00 m asx11-fbp.300 as-i extension cable 5.00 m asx11-fbp.500 as-i round cable and accessories for bus extension bus cable and coupling accessories designation cable length order code as-i extension cable 100 m asc11-fbp.999 as-i round cable, male conn. asm11-fbp.0 as-i round cable, female conn. asf11-fbp.0 as-i flat-cable branch circuit with m12 socket ast11-fbp.0 as-i addressing device, power unit, miscellaneous accessories designation order code as-i addr. device, incl. plug-in power unit asa21-fbp.0 power unit ps 24v/5a, adjustable systron ps24/5 address signs for fieldbusplug cal11-fbp.0 field bus plug direct field bus plug performance st04901 st05001 st05101 st05501 st05701 st05601
abb limited 2/ 52 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 fbp fieldbusplug devicenet fieldbus connectors and accessories (please consult us for availability of other protocol?) devicenet fieldbusplug ready-made devicenet fieldbus interface with various cable lengths. ?applicable on all fbp motor starters and other devices ?degree of protection ip65, diagnostic led designation cable length order code fieldbusplug devicenet 0.25 m dnp21-fbp.025 devicenet 0.50 m dnp21-fbp.050 devicenet 1.00 m dnp21-fbp.100 devicenet 5.00 m dnp21-fbp.500 accessories for the devicenet bus connector devicenet round cable for bus junctions ready-made bus cable with an m12 connector and an open cable end. ?application on bus junctions such e.g. devicenet couplers or devices with an integrated devicenet interface designation cable length order code devicenet round cable 0.50 m dnf11-fbp.050 with female connector devicenet round cable 0.50 m dnm11-fbp.050 with male connector devicenet round cable for bus extension ready-made bus cable with m12 male and female connectors designation cable length order code devicenet extension cable 1.00 m dnx11-fbp.100 devicenet extension cable 3.00 m dnx11-fbp.300 devicenet extension cable 5.00 m dnx11-fbp.500 devicenet round cable and accessories for bus extension bus cable and coupling accessories designation cable length order code devicenet extension cable 100 m dnc11-fbp.999 devicenet round cable, male conn. dnm11-fbp.0 devicenet round cable, female conn. dnf11-fbp.0 termination resistor, power unit, miscellaneous accessories designation extra information order code devicenet termination resistor 120 ohm dnr11-fbp.120 power unit ps 24v/5a, adjustable systron ps24/5 b10 st05301 st05201 st04801 st05501 st05701 st05401
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 53 notes
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 54 softstarters description softstarters type ps s abb? solid state starter range is used when it is important to have a smooth start-up of various types of motor drives. instead of switching directly to full voltage the softstarter ensures a gradual voltage increase. ps s 03?s s 25 is a compact solution for small motors. mounting is on 35 mm din-rail. this small softstarter has a built-in bypass contact. ps s 18/30?s s 300/515 for normal duty applications and connection both ?n line?and ?nside delta?(compare the connection with a standard y/d starter). the result of ?nside delta?connection is a 42 % reduction of the current exposed to the softstarter. it will then be possible, for example, to start and run a 100 a motor using a 58 a softstarter. an optional ?urrent limit?function is available. two signal relays are built in as standard. this softstarter has a service factor of 1.15, which means that the maximum operational current is i e (rated current) x1.15. example: the ps s 18/30 connected in-line has an i e of 18 a. the maximum operational current is then 1.15 x 18 a = 20.7 a. the operator panels for ps s, ps d and ps dh have leds, potentiometers and switches for indication and settings. in-line and inside-delta connection of ps s 18/30?00/515
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 55 softstarters general technical data ps s 03...ps s 25 and ps s 18/30...ps s 300/515 ps s03...ps s 12 ps s 25 ps s 18/30...ps s 300/515 rated insulation voltage ui v 630 630 690 rated operational coltage ue v 220 - 230 220 - 230 200 - 690 400 - 415 400 - 415 - 480 - 500 480 - 500 - 600 600 - starting capacity at max. 5 x ie for 5 sec 5 x ie for 5 sec 4 x ie for 10 sec rated current ie number of starts per hour 62) 6 2) 30 5) overload capability overload class a 10 10 10 service factor % 100 100 115 (ps s 18/30...250/430) 110 (ps s 300/515) ambient temperature during operation ? -20 ?+50 -20 ?+50 -25 ?+60 1) during storage ? -40 ?+70 -40 ?+70 -40 ?+70 degree of protection main circuit ip20 ip20 ip20 (ps s 18/30-500...44/76-500) ip10 (pss 50/85-500...72/124-500) ip10 (ps s 18/30-690...75/124-690) ip00 (ps s 85/147...300/515) supply and control circuit ip20 ip20 ip20 settings ramp time during start s 0.5 ?6.5 -+15% 0.5 ?10 -+10% 1 ?30 ramp time during stop s 0.5 ?8 -+25% 0.5 ?20 -+10% 0 ?30 initial voltage during start % 0 ?85 -+15% 0.5 ?50 -+5% 30 ?70 current limit voltage xie no no 1.5 ?4 3) switch for inside delta connection on/off no no yes signal relay by-pass signal no 4) no 4) yes fault signal no no yes rated operational voltage ue v - - 250 rated thermal current ith a - - 5 rated operational current at ac-15 (ue=250) a - - 1.5 signal indication led ready to start/stand by on green green green ramping up/down yellow yellow (flashing) no completed start ramp t.o.r. yellow yellow green general fault f1 - red red external fault f2 - - red 1) above 40?, up to max 60?, reduce the rated current with 0.8% per ?. 2) when more than 6 starts per hour are required, contact your sales office. 3) only if current transformer is connected (accessory). 4) the unit has built in by-pass contacts (ac-53b). 5) valid for 50% on time and 50% off time. 3.5 x ie for 7 sec., if other data is required, contact your sales office
abb limited 2/ 56 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 soft starters soft starter ps s 03?5, ps s18/30?00/515 ps s 03...25 for normal starts motor motor rating rating 230 v 400 v 230 v 400 v currrent pe pe pe pe ie kw kw kw kw a order code - 1.1 - - 3 ps s 03-400b - 5.5 - - 12 ps s 12-400b - 11.0 - - 25 ps s 25-400b control voltage 40-110v ac/dc, 110-440 vac. ps s 18/30?42/245 for normal starts inline inside delta motor motor rating rating 230 v 400 v 500 v 690 v currrent 230 v 400v 500v 690v current pe pe pe pe ie pe pe pe pe ie kw kw kw kw a kw kw kw kw a order code 4 7.5 11 - 18 7.5 15 18.5 - 30 ps s 18/30-500 7.5 15 18.5 - 30 12.5 25 30 - 52 ps s 30/52-500 9 18.5 22 - 37 15 30 37 - 64 ps s 37/64-500 11 22 25 - 44 22 37 45 - 76 ps s 44/76-500 12.5 25 30 - 50 25 45 55 - 85 ps s 50/85-500 15 30 37 - 60 30 55 75 - 105 ps s 60/105-500 18.5 37 45 - 72 37 59 80 - 124 ps s 72/124-500 22 45 55 - 85 40 75 90 - 147 ps s 85/147-500 30 55 75 - 105 55 90 110 - 181 ps s 105/181-500 37 75 90 - 142 75 132 160 - 245 ps s 142/245-500 45 90 110 - 175 90 160 200 - 300 ps s 175/300-500 75 132 160 - 250 132 220 295 - 430 ps s 250/430-500 90 160 200 - 300 160 257 355 - 515 ps s 300/515-500 code letter for supply voltage is f = 110-120v, 50/60hz; l = 220-240v 50/60hz code letter dor fault fignal relay is blank = no; c = nc note: for heavy duty starting and 690v applications. please consult us.
abb limited 2/ 57 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 soft starters accessories ps s 18/3?00/515 cur r ent transformer for cur r ent limit function to be connected to terminals 11 and 12 on the soft starter. the setting range (1.5 ?4) corresponds to a multiple of the transformer ratio. technical data below shows transformer ratio and number of turns for the primary winding. current transformer for softstarter weight kg order code 60/1 ?2 turns ps s 18/30 0.30 ps ct-60 40/1 ?1 turn ps s 30/52 0.30 ps ct-40 50/1 ?1 turn ps s 37/64 0.30 ps ct-50 60/1 ?1 turn ps s 44/76 0.30 ps ct-60 75/1 ?1 turn ps s 50/85 0.30 ps ct-75 75/1 ?1 turn ps s 60/105 0.30 ps ct-75 100/1 ?1 turn ps s 72/124 0.25 ps ct-100 125/1 ?1 turn ps s 85/147 0.25 ps ct-125 150/1 ?1 turn ps s 105/181 0.25 ps ct-150 200/1 ?1 turn ps s 142/245 0.25 ps ct-200 250/1 ?1 turn ps s 175/300 0.25 ps ct-250 400/1 ?1 turn ps s 250/430 0.25 ps ct-400 400/1 ?1 turn ps s 300/515 0.25 ps ct-400 cable connectors for cu cables (set of 3) wire range tightening for softstarter weight order code torque max. nm kg 6-185 mm 2 16 ps s 85/147?42/245 0.2 1sda023354r1 2x(50-1210) mm 2 16 ps s 85/147?42/245 0.3 lz 185-2c/120 16-240 mm 2 25 ps s 175/300?00/515 0.4 1sda023368r1 cable connectors for ai and cu cables (set of 3) wire range tightening torque for softstarter weight kg order code 35-95 mm 2 13.35 ps s 85/147?42/245 0.1 1sda023356r1 25-150 mm 2 31 ps s 85/147?42/245 0.1 1sda023357r1 120-240 mm 2 43 ps s 175/300?00/515 0.1 1sda023379r1 t erminal shrouds (set of 2) for softstarter weight kg order code for cable connectors ps s 85/147?42/245 0.1 lt 185-ac for compression lugs ps s 85/147?42/245 0.1 lt 185-al for cable connectors ps s 175/300?00/515 0.2 lt 300-ac for compression lugs ps s 175/300?00/515 0.2 lt 300-al t erminal nut washer (set of 2) for softstarter weight kg order code ps s 85/147?42/245 0.2 le 185 ps s 175/300?00/515 0.3 le 300 t erminal shrouds (set of 2) for softstarter weight kg order code ps s 18/30...44/76 0.1 ps lw-44 ps s 50/85?2/124 0.15 ps lw-72 ps s 85/147?42/245 0.25 lw 185 ps s 175/300?00/515 0.4 lw-300
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 58 pilot devices, compact range non-illuminated same front design for both the modular and the compact range. robust actuators in clear colors with large text and push area. samples of accessories
abb limited 2/ 59 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 pilot devices compact range pushbuttons, non-illuminated contacts included momentary *maintained momentary *maintained no nc flush button flush button extended button extended button 1 - cp1-10 -10 cp2-10 -10 cp3-10 -10 cp4-10 -10 2 - cp1-10 -20 cp2-10 -20 cp3-10 -20 cp4-10 -20 - 1 cp1-10 -01 cp2-10 -01 cp3-10 -01 cp4-10 -01 - 2 cp1-10 -02 cp2-10 -02 cp3-10 -02 cp4-10 -02 1 1 cp1-10 -11 cp2-10 -11 cp3-10 -11 cp4-10 -11 chrome bezel available on request colour code letter red r ordering example green g requested: a compact pushbutton, momentary, with red yellow y extended button and one no contact. blue l order: 1 piece of cp3-10r-10 white w black b grey u contacts included momentary *maintained flush button, white extended button, black with black i with black ii with white 0 1 - cp1-110w-10 cp1-210w-10 - - 1 - - cp3-310b-01 chrome bezel available on request *maintained available sept 2003 onwards
abb limited 2/ 60 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 selector switches, non-illuminated t wo position contacts included maintained maintained momentary no nc 1 - c2ss1-10 -10 c2ss2-10 -10 c2ss3-10 -10 2 - c2ss1-10 -20 c2ss2-10 -20 c2ss3-10 -20 - 1 c2ss1-10 -01 c2ss2-10 -01 c2ss3-10 -01 - 2 c2ss1-10 -02 c2ss2-10 -02 c2ss3-10 -02 1 1 c2ss1-10 -11 c2ss2-10 -11 c2ss3-10 -11 chrome bezel available on request colour code letter red r black b grey u three position contacts included maintained momentary momentary momentary no nc 2 - c3ss1-10 -20 c3ss2-10 -20 c3ss3-10 -20 c3ss7-10 -20 - 2 c3ss1-10 -02 c3ss2-10 -02 c3ss3-10 -02 c3ss7-10 -02 1 1 c3ss1-10 -11 c3ss2-10 -11 c3ss3-10 -11 c3ss7-10 -11 ordering example requested: a red compact selector switch with three positions, momentary, spring return from a to b and maintained position in c. with 2 nc contacts. order: 1 piece of c3ss7-10r-02 pilot lights (max. 250v 3w) pilot light ba 9s base colour order code red cl-100r green cl-100g yellow cl-100y blue cl-100l white cl-100w clear cl-100c direct supply. max. 250v 3w. use filament bulb for best light. alight diffusing lens is recommended for use with led and neon bulbs.
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 61 t echnical data standards iec 73, 529, 947-5-1, 947-5-5 en 50 013, 60 947-5-1 ul 508 csa c22.2 no. 14 degree of protection operators compact pushbutton ip66 compact pilot lights ip66 compact selector switch ip66 electrical functions terminals ip20 mechanical life pushbuttons 0.5 million operations selector switches 0.5 million operations temperature ambient temperature during operation -25 to +70 ? storage temperature -30 to +85 ? terminals plus-minus pozidrive size 2 connectable area min. 1 x 0.5mm2 max. 2 x 1.5mm2/ 2 x awg14 contacts ratings as per ul, csa, nema c300, r300 rated insulation voltage 250 v rated thermal current 2.5 a rated operational current at 120 v 1.5 a 240 v 0.75 a ratings as per iec 947-5-1 rated insulation voltage 300 v rated thermal current, ith 5 a rated operational current ie utilization category ac 15, at 120 v 1.5 a 240 v 1 a utilization category dc 13, at 24 v 0.3 a 125 v 0.2 a short circuit protection max. fuse at 1 ka 16 a ordinary 10 a delayed pilot light max. 3w, 240 v pilot devices, compact range t echnical data extended button flush button dimensions - compact pushbutton compact selector switch compact pilot light
abb limited 2/ 62 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 voltages see page xx colour code - replace * with colour contact blocks see page xx order example: cbk-cpif 6r (illuminated pushbutton c/w lamp block & lamp - 6v direct -red) colour code r = red g = green y = yellow l = blue b = black 1) w = white 2) c = clear 2) 1) only available for non-illuminated pushbuttons 2) not available for led lamps
abb limited 2/ 63 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 pushbutton & pilot devices cbk 22mm emergency stop (complies with en 60947-55) description order code 40mm emergency stop twist to release kpmt3-20r pull to release kpmp3-20r momentary kpm1-20r 60mm emergency stop twist to release kpmt4-20r pull to release kpmp4-20r momentary kpm2-20 40mm illuminated emergency stop twist to release kpmt3-21r pull to release kpmp3-21r momentary kpm1-21r 60mm illuminated emergency stop twist to release kpmt4-21r pull to release kpmp4-21r momentary kpm2-21r mushroom and doubleheaded pushbuttons. 30mm mushroom pushbutton twist to release cbk-pmt3r * push pull cbk-pmp3r * momentary cbk-pm3r * mushroom lockable pushbutton 40mm maintained (red only) cbk-pmk40r 45mm maintained (red only) cbk-pmk r double pushbutton momentary (start stop) cbk-2p1 c momentary (blank) cbk-2p4 c *standard actuator colour is red if black is required replace r with b eg. cbk-pm3b = 30mm mushroom in black contact blocks see page xx lamp blocks see page xx
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 64 3 position standard actuator colour is black if other colours are required replace * r = red g = grey eg. cbk-c2bmkr = 2 pos switch in red contact blocks see page xx 2 position pushbutton & pilot devices cbk 22mm selector switches non-illuminated description bezel type order code non-illuminated 2 pos. short selector switches chrome plastic cbk-c2bmk * maintained (b&c) chrome cbk-m2bmk * non-illuminated 2 pos. short selector switches chrome plastic cbk-c2bsk * spring return (c to b) chrome cbk-m2bsk * non-illuminated 2 pos. short selector switches chrome plastic cbk-c2amk * maintained (a&c) chrome cbk-m2amk * non-illuminated 2 pos. long selector switches chrome plastic cbk-c2bml * maintained (b&c) chrome cbk-m2bml * non-illuminated 2 pos. long selector switches chrome plastic cbk-c2bsl * spring return (c to b) chrome cbk-m2bsl * non-illuminated 2 pos. long selector switches chrome plastic cbk-c2aml * maintained (a&c) chrome cbk-m2aml * non-illuminated 3 pos. short selector switches chrome plastic cbk-c3mk * maintained (a,b&c) chrome cbk-m3mk * non-illuminated 3 pos. short selector switches chrome plastic cbk-c3sk * spring return (a&c to b) chrome cbk-m3sk * non-illuminated 3 pos. short selector switches chrome plastic cbk-c3srk * spring return (c to b) maintained (a) chrome cbk-m3srk * non-illuminated 3 pos. long selector switches chrome plastic cbk-c3ml * maintained (a,b&c) chrome cbk-m3ml * non-illuminated 3 pos. long selector switches chrome plastic cbk-c3sl * spring return (a&c to b) chrome cbk-m3sl * non-illuminated 3 pos. long selector switches spring return (c to b) chrome plastic cbk-c3srl * maintained (a) chrome cbk-m3srl * note: black plastic bezels available on request
abb limited 2/ 65 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 pushbutton & pilot devices cbk 22mm 2 position 3 position contact blocks see page xx lamp blocks see page xx colour code - replace * with colour r = red g = green y = yellow l = blue selector switches illuminatec (translucent actuator) description bezel type order code illuminated 2 pos. short selector switches chrome plastic cbk-c2bmki * maintained (b&c) chrome cbk-m2bmki * illuminated 2 pos. short selector switches chrome plastic cbk-c2bski * spring return (c to b) chrome cbk-m2bski * illuminated 2 pos. short selector switches chrome plastic cbk-c2amki * maintained (a&c) chrome cbk-m2amki * illuminated 2 pos. long selector switches chrome plastic cbk-c2bmli * maintained (b&c) chrome cbk-m2bmli * illuminated 2 pos. long selector switches chrome plastic cbk-c2bsli * spring return (c to b) chrome cbk-m2bsli * illuminated 2 pos. long selector switches chrome plastic cbk-c2amli * maintained (a&c) chrome cbk-m2amli * illuminated 3 pos. short selector switches chrome plastic cbk-c3mki * fixed (a,b&c) chrome cbk-m3mki * illuminated 3 pos. short selector switches chrome plastic cbk-c3ski * spring return (a&c to b) chrome cbk-m3ski * illuminated 3 pos. short selector switches spring return (c to b) chrome plastic cbk-c3srki * maintained (a) chrome cbk-m3srki * illuminated 3 pos. long selector switches chrome plastic cbk-c3mli * maintained (a,b&c) chrome cbk-m3mli * illuminated 3 pos. long selector switches chrome plastic cbk-c3sli * spring return (a&c to b) chrome cbk-m3sli * illuminated 3 pos. long selector switches spring return (c to b) chrome plastic cbk-c3srli * maintained (a) chrome cbk-m3srli *
abb limited 2/ 66 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 2 position 3 position contact blocks see page 2/69 n.b . different keys are available for the selector switches on request the standard unit has key type 71. for key type 72 add a "2" at the end of the reference or for key type 73 add a "3". eg. cbk-s2km1 key 71. cbk-s2km12 key 72. cbk-s2km13 key 73. pushbutton & pilot devices cbk 22mm key operated selector switches description bezel type order code key operated 2 pos. selector switches maintained, key removable all pos. chrome cbk-s2km4 maintained, key removable (b) chrome cbk-s2km1 momentary, key removable (b) chrome cbk-s2ks1 key operated 3 pos. selector switches maintained, key removable all pos. chrome cbk-s3km4 momentary, key removable all pos. spring ret. from (a & c to b) chrome cbk-s3ks4 maintained, key removable (b) chrome cbk-s3km2 momentary, key removable (b) spring ret. from (a&c to b) chrome cbk-s3ks2 momentary, key removable (a) spring ret. from (c to b) chrome cbk-s3ksr1 key operated maintained pushbutton, locks when depressed release via key. key removable both positions. chrome cbk-pkm1
abb limited 2/ 67 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 pushbutton & pilot devices cbk 22mm pilot lights voltage description order code 6v lamp & lamp block cbk-klf6 * 12v lamp & lamp block cbk-klf7 * 24v lamp & lamp block cbk-klf8 * 48v lamp & lamp block cbk-klf9 * 120v lamp & lamp block cbk-klf1 * 110/60v lamp, lamp block & resistor cbk-klr1 * 240/120v lamp, lamp block & resistor cbk-klr2 * 110/6v lamp, lamp block & transformer cbk-klt1 * 240/6v lamp, lamp block & transformer cbk-klt2 * 415/6v lamp, lamp block & transformer cbk-klt3 * 480/6v lamp, lamp block & transformer cbk-klt4 * 24v led lamp & lamp block cbk-klfl8 * 110/24v led lamp, lamp block & resistor cbk-klrl1 * 110/24v led lamp, lamp block & transformer cbk-kltl1 * 240/24v led lamp, lamp block & transformer cbk-kltl2 * 415/24v led lamp, lamp block & transformer cbk-kltl3 * 480/24v led lamp, lamp block & transformer cbk-kltl4 * lamp holder
abb limited 2/ 68 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401
abb limited 2/ 69 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 pushbutton & pilot devices cbk 22mm actuator mounted blocks base mounted blocks rear mounted blocks contact block holders contact blocks description type contact order code contact blocks are colour standard 1 n/o cbk-cb10 coded to easlly identify 1 n/c cbk-cb01 the contact configuration. green = n/o red = n/c contact blocks are colour gold plated low 1 n/o cbk-cb10g coded to easlly identify energy contacts 1 n/c cbk-cb01g the contact configuration. green = n/o red = n/c double contact block 2 n/o cbk-cb20 for use with 5 block holder (i.e. outer 2 n/c cbk-cb02 positions) and 3 block holder for 1 n/o + 1 n/c cbk-cb11 selector switches when centre position is required contact block (rear mounted) contact blocks are colour standard 1 n/o cbk-cbr10 coded to easlly identify 1 n/c cbk-cbr01 the contact configuration. green = n/o red = n/c contact blocks are colour gold plated low 1 n/o cbk-cbr10g coded to easlly identify energy contacts 1 n/c cbk-cbr01g the contact configuration. green = n/o red = n/c double contact block for 2 n/o cbk-cb20b use when 5 contacts are 2 n/c cbk-cb02b required (i.e. outer positions) 1 n/o + 1 n/c cbk-cb11b and selector switches when centre position is required 3 contact block holder cbk-ch 5 contact block holder cbk-h5 safety holder for emergency stop (3 contact block holder) kcbhs-00 the safety holder can only be used on emergency stop pushbuttons
abb limited 2/ 70 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 pushbutton & pilot devices accessories accessories protective membrane of transparent, heat and cold resistant rubber. does not harden at low temperature. gives ip 67 degrees of protection. when membrane is used, remove the gasket. for operator with weight (kg) order code flush button 0.002 cbk-kxb extended button 0.002 cbk-kxbe double pushbutton 0.004 cbk-xb2 mounting tool used for tightening the nut of the attachment device. 0.100 1sfa616920r8015 30mm adapters for use when fitting the 22mm pilot devices in 30mm mounting holes. (1.5mm - 4mm panels) for use with 22mm compact pilot light black plastic 0.010 1sfa616920r8029 metal 0.035 1sfa616920r8030 lamp changing tool designed for two different lamp diameters. the larger diameter fits filament bulbs and leds and the smaller diameter fits neon bulbs. lamp changing tool 0.002 ka1-8072 legend plates engraved fixed plates with symbol/text symbol / text for push button legend plate material weight order code off silver-grey aluminium 0.002 cbk-npe10 on silver-grey aluminium 0.002 cbk-npe11 start silver-grey aluminium 0.002 cbk-npe19 stop silver-grey aluminium 0.002 cbk-npe20 symbol / text for two-position selector switch centre right legend plate material weight order code hand auto silver-grey aluminium 0.002 cbk-npe22 off on silver-grey aluminium 0.002 cbk-npe24 stop start silver-grey aluminium 0.002 cbk-npe25 symbol / text for three-position selector switch left centre right legend plate material weight order code hand o auto silver-grey aluminium 0.002 cbk-npe26 slow off fast silver-grey aluminium 0.002 cbk-npe27 blank - aluminium (1-2 line) cbk-npe28 blank - aluminium (2-3 line) cbk-npe29 blank - plastic (1-2 line) cbk-npe28p blank - plastic (2-3 line) cbk-npe29p emergency stop (70mm) cbk-npe30
abb limited 2/ 71 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 pushbutton stations non-metallic ip 54/65 description order code 1 element enclosure ip65 cbk-ep1 2 element enclosure ip65 cbk-ep2 3 element enclosure ip65 cbk-ep3 4 element enclosure ip65 cbk-ep4 6 element enclosure ip65 cbk-ep6 1 element yellow enclosure (only) ip65 cbk-epy 1 element complete emergency stop station ip54 cbk-ep1es40r c/w twist to release mushroom headed button with 2 n/c contacts metallic enclosures available on request
abb limited 2/ 72 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 switching power supplies cp range the switching power supplies cp offer many advantages in comparison to conventional supplies: ?din-rail mount compact modules ?constant output voltage with good regulation ?low weight ?culus listet, ul 1604 class i, div 2 ?high efficiency ?en 50178 (vde 0160) ?low heating ?short-circuit and overload proof ?wide range of supply voltage ?fused input type supply voltage output voltage weight order code cp-5/3.0 90 - 260v ac/ 5vdc/3a 0.220 1svr423418r3000 105 - 260v dc frequency, ac input: 47 - 400hz inrush current 25? ( 2ms): 7.5a output load hold time: 10ms at 100% load internal input fuse: 3.0a(t) input current at output voltage: 5v dc ?3% nominal load: 0.4a(90v ac) / 0.2a (260v ac) output current: 3a type supply voltage output voltage weight order code cp-6/3.0 90-260vac/ 6vdc/3a 0.220 1svr423418r4000 105-260vdc frequency, ac input: 47 - 400hz inrush current 25? ( 2ms): 7.5a output load hold time: 10ms at 100% load internal input fuse: 3.0a(t) input current at output voltage: 6v dc ?3% nominal load: 0.5a(90v ac) / 0.25a (260v ac) output current: 3a type supply voltage output voltage weight order code cp-12/2.0 90-260vac/ 12vdc/2a 0.220 1svr423418r1000 105-260vdc frequency, ac input: 47 - 400hz inrush current 25? ( 2ms): 7.5a output load hold time: 10ms at 100% load internal input fuse: 3.0a(t) input current at output voltage: 12v dc ?3% nominal load: 0.6a (90v ac) / 0.27a (260v ac) output current: 2a adjustable output voltage type supply voltage output voltage weight order code cp-12/2.0 adj 90-260vac/ 12vdc/2a 0.220 1svr423418r1100 105-260v dc frequency, ac input: 47 - 400hz inrush current 25? ( 2ms): 33a output load hold time: 10ms at 100% load internal input fuse: 3.0a(t) input current at output voltage: 12v dc ?3% nominal load: 0.7a(90v ac) / 0.3a (260v ac) output current: 2a / 48w type supply voltage output voltage weight order code cp-24/0.3 adj 90-260vac/ 12vdc/2a 0.220 1svr423418r1100 105-260v dc frequency, ac input: 47 - 400hz inrush current 25? ( 2ms): 7.5a output load hold time: 10ms at 100% load internal input fuse: 3.0a(t) input current at output voltage: 24v dc ?3% nominal load: 0.2a(90v ac) / 0.1a (260v ac) output current: 0.3a cp-5/3.0 cp-24/0.3
abb limited 2/ 73 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 switching power supplies cp range type supply voltage output voltage weight order code cp-24/0.5 90 - 260v ac/ 24v dc/0.5a 0.220 1svr423414r0000 105 - 260v dc frequency, ac input: 47 - 440hz output load hold time: 10ms at 100% load input current at nominal load: 0.3a (90v ac) / 0.15a (230vac) inrush current 25? ( 2ms): 33a internal input fuse: 3.0a(t) output voltage: 24v dc ?3% output current: 0.5a / 7.2w type supply voltage output voltage weight order code cp-24/1.0 90 - 260v ac/ 24v dc/1a 0.220 1svr423418r0000 105 - 260v dc frequency, ac input: 47 - 440hz output load hold time: 10ms at 100% load input current at nominal load: max. 0.58a (90v ac) typ. 0.45a (115vac) typ. 0.27a (230vac) inrush current 25? ( 2ms): 7.5a (260v) internal input fuse: 3.0a(t) output voltage: 24v dc ?3% output current: 1a adjustable output voltage type supply voltage output voltage weight order code cp-24/1.5adj 90 - 260v ac/ 24v dc/1.5a 0.220 1svr423418r5000 105 - 260v dc frequency, ac input: 47 - 440hz output load hold time: 20ms at 100% load input current at nominal load: max. 0.8a (90vac) typ. 0.7a (117vac) typ. 0.39a (230vac) inrush current 25? ( 2ms): 33a internal input fuse: 3.0a(t) output voltage: 24v dc ?3% output current: 1.5a / 36w type supply voltage output voltage weight order code cp-24/2.0 90 - 140v ac 24vdc/2a 0.300 1svr423417r0000 cp-24/2.0 140v - 260v ac/ 24vdc/2a 0.300 1svr423417r1000 160 - 260v dc frequency, ac input: 47 - 63hz (90 - 140vac) 47 - 440hz (140-260vac / 160-260vac) output load hold time: 10ms at 100% load input current at nominal load: max 1.0a (90v ac) / max. 0.8a (140vac) typ. 0.9a (230vac typ. 0.45a (230vac) inrush current 25? ( 2ms): 23a (140vac / 9a (260vac) internal input fuse: 3.0a(t) output voltage: 24v dc ?3% output current: 2a / 48w cp-24/0.5
abb limited 2/ 74 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 switching power supplies cp range adjustable output voltage type supply voltage output voltage weight order code cp-24/2.0adj 140 - 260v ac/ 24v dc/2a 0.280 1svr423417r1100 160 - 260v dc frequency, ac input: 47 - 440hz output load hold time: 10ms at 100% load input current at nominal load: max. 1.5a (90v ac) typ. 1.1a (115v ac) typ. 0.52a(230vac) inrush current 25? ( 2ms): 40a (260v) internal input fuse: 2.0a(t) output voltage: 24v dc ?3% output current: 2a / 48w type supply voltage output voltage weight order code cp-24/4.2 90 - 260v ac/ 24v dc/4.2a 0.580 1svr423416r1000 127 - 260v dc frequency, ac input: 47 - 63hz output load hold time: 20ms at 100% load input current at nominal load: max. 1.5a (90v ac) typ. 1.1a (115vac) typ. 0.52a (230vac) inrush current 25? ( 2ms): 40a (260v) internal input fuse: 2.0a(t) output voltage: 24v dc ?3% output current at t 55?: v in 90-260vac - 4.2a / v in 127-260vac - 4.2a type supply voltage output voltage weight order code cp-24/5.0 90 - 260v ac/ 24vdc/5.0a 0.580 1svr423416r0000 127 - 260v dc frequency, ac input: 47 - 63hz output load hold time: 10ms at 100% load input current at nominal load: max. 1.8a (90vac) typ. 1.3a (115vac) typ. 0.63a (230vac) inrush current 25? ( 2ms): 40a (260v) internal input fuse: 2.0a(t) output voltage: 24v dc ?3% output current: t 40? t > 40? t = 55? v in > 45? 5a - 0.054a/? 4.2a v in < 90vdc or < 140vac 5a - 0.054a/? 4.2a adjustable output voltage type supply voltage output voltage weight order code cp-24/5.0 adj 90v - 260v ac/ 24vdc/5a 0.580 1svr423416r0100 127 - 260v dc frequency, ac input: 47 - 63hz output load hold time: 10ms at 100% load input current at nominal load: max 1.8a (90v ac) typ. 1.3a (115vac typ. 0.63a (230vac) inrush current 25? ( 2ms): 40a (260v) internal input fuse: 2.0a(t) output voltage: 24vdc ?3% (23-28vdc adjustable with poti., max. 120w) output current: t 40? t > 40? t = 55? v in > 45? 5a/120w - 1.33w/? 4.2a/100w v in < 90vdc or < 140vac 5a/120w - 1.33w/? 4.2a/100w cp-24/2.0 adj cp-24/4.2 cp-24/5.0 adj
abb limited 2/ 75 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 switching power supplies cp range adjustable output voltage type supply voltage output voltage weight order code cp-24/10 adj 93 - 132vac/ 24v dc/10a 1.050 1svr432415r0000 187 - 264v dc frequency, ac input: 47 - 63hz output load hold time: 20ms at 100% load input current at nominal load: max. 4.3a (93vac) typ. 3.5a (115vac) typ. 1.7a (230vac) inrush current 25? ( 1ms): max. 69a (230v) internal input fuse: 4.0a(t) output voltage: 24v dc ?1% (24 - 28vdcadjustable with a screwdriver) output current: t 60? t > 60? t = 70? v in 93 - 132vac 10a - 2%/? 8a v in 187 - 264vdc 10a - 2%/? 8a redundant module type input current output current weight order code cp-rud 5a max. 5a max. 0.150 1svr423418r9000 monitors two cp range power supplies up to 5a current each. if one power supply fails the cp-rud automatically switches to the alternative supply without interruption of the load current. max. voltage 40v. adjustable output voltage type supply voltage output voltage weight order code cp-24/20 adj 93 - 123vac/ 24v dc/20a 2.200 1svr423415r1000 187 - 264vac frequency, ac input: 47 - 63hz output load hold time: 15ms at 100% load input current at nominal load: max. 8.9a (93vac) typ. 7.2a (115vac) typ. 3.5a (230vac) inrush current 25? ( 2ms): max. 65a (230v) internal input fuse: 10a(t) output voltage: 24vdc ?1% (28 - 24vdc adjustable with screwdriver) output current: t 60? t 60? t = 70? v in 93 - 132vac 20a - 2%/? 16a v in 187 - 264vdc 20a - 2%/? 16a type supply voltage output voltage weight order code cp-48/.07 90 - 260v ac/ 48v dc/0.7a 0.300 1svr423418r6000 105 - 260v dc frequency, ac input: 47 - 440hz output load hold time: 10ms at 100% load input current at nominal load: max 0.8a (90v ac) typ. 0.7a (115vac) typ. 0.35a (230vac) inrush current 25? ( 2ms): 33a (260v) internal input fuse: 3.0a(t) output voltage: 48v dc ?3% output current: 0.7a t u > 45? - 10ma/? v in < 105vac/120vdc - 6.667ma/v cp-24/10 adj cp-24/20 adj cp-48/.07
abb limited 2/ 76 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 linear power supplies cp-l range all power supplies are dinrail mountable and available with 230v or 115vac input voltage, and deliver a stable and regulated dc output voltage with a low residual ripple of ?1%. ?the ouput is short-circuit and overload protected ?a led provides status operation type supply voltage output voltage weight order code cp-l5/1.0 115vac 5vdc/1a 0.820 1svr419500r3000 230vac 5vdc/1a 0.820 1svr419500r3100 frequency, ac input: 47 - 63hz mains buffering: min. 5 ms with 100% load input current at nominal load: typ. 0.16a, 115v / typ./ 0.08a, 230v internal input fuse: 0.2a (t) 115v / 0.125a (t) 230v type supply voltage output voltage weight order code cp-l12/0.5 115vac 12vdc/0.5a 0.820 1svr419501r1000 230vac 12vdc/0.5a 0.820 1svr419501r1100 cp-l12/1.0 115vac 12vdc/1a 0.780 1svr419501r3000 230vac 12vdc/1a 0.780 1svr419501r3100 frequency, ac input: 47 - 63hz mains buffering: min. 5 ms with 100% load input current at nominal load: 0.5a: typ. 0.14a / typ. 0.07a 1a: 0.32a / 0.16 (t) internal input fuse: 0.5a: 0.2a(t) / 0.125a (t) 1a: 0.4a (t) / 0.2a (t) type supply voltage output voltage weight order code cp-l15/0.5 115vac 15vdc/0.5a 0.820 1svr419502r1000 230vac 15vdc/0.5a 0.820 1svr419502r1100 cp-l15/1.0 115vac 15vdc/1a 0.780 1svr419502r3000 230vac 15vdc/1a 0.780 1svr419502r3100 frequency, ac input: 47 - 63hz mains buffering: min. 5 ms with 100% load input current at nominal load: 0.5a: typ. 0.14a / typ. 0.07a 1a: 0.35a / 0.175 (t) internal input fuse: 0.5a: 0.2a(t) / 0.125a (t) 1a: 0.4a (t) / 0.2a (t) cp-l 5vdc, 12vdc 15vdc, 24vdc
abb limited 2/ 77 www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 linear power supplies cp-l range type supply voltage output voltage weight order code cp-l24/0.25 115vac 24vdc/0.25a 0.820 1svr419503r0000 230vac 24vdc/0.25a 0.820 1svr419503r0100 cp-l24/0.75 115vac 24vdc/0.75a 1.050 1svr419503r2000 230vac 24vdc/0.75a 1.050 1svr419503r2100 frequency, ac input: 47 - 63hz mains buffering: min. 5 ms with 100% load input current at nominal load: 0.25a: typ. 0.14a / typ. 0.07a 0.75a: 0.35a / 0.175 (t) internal input fuse: 0.25a: 0.2a(t) / 0.125a (t) 0.75a: 0.4a (t) / 0.2a (t) type supply voltage output voltage weight order code cp-l?2/0.5 115vac ?12vdc/0.5a 1.070 1svr419511r1000 230vac ?12vdc/0.5a 1.070 1svr419511r1100 frequency, ac input: 47 - 63hz mains buffering: min. 5 ms with 100% load input current at nominal load: typ. 0.35a, 115v / typ. 0.16a, 230v internal input fuse: 0.4a (t) 115v / 0.2a (t) 230v type supply voltage output voltage weight order code cp-l?5/0.5 115vac ?15vdc/0.5a 1.070 1svr419512r1000 230vac ?15vdc/0.5a 1.070 1svr419512r1100 frequency, ac input: 47 - 63hz mains buffering: min. 5 ms with 100% load input current at nominal load: typ. 0.35a, 115v / typ. 0.175a, 230v internal input fuse: 0.4a (t) 115v / 0.2a (t) 230v ?12vdc stabilised ?15vdc stabilised
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 78 power supplies cp range t echnical data description cp-5/3.0 cp-6/3.0 cp-12/2.0 cp-12/2.0 adj cp-24/0.3 residual ripple / noise max.50mvpp max.300mvss max.200mvss max.100mvss deviation of ouput with input change max. ?.5% max. ?.1% max. ?.5% deviaton of output with static load change max. ?.5% dev. of output with static load change 10 - 90% max. 5% short circuit protection overcurrent switch off with autmomatic restart overload protection overtemperature and overcurrent switch off reset after thermal overload disconnection of ac power input min. 30 s standards, tests electrical safey standards en 50178 (vde 0160) / ul 508 / csa 22.2 galvanic isolation reliable isolation acc. to iec 644-1, dinvde 0106-101 voltage withstand input <-> output 2.5kvac, 3 kvac type test clearance and creepage distances overvoltage category 2, pollutoin degree 2 electromagnetic compatibility (emc-tests) esd: en 61000-4-2 level 3 6/8kv acc. to en 50082-2 rf field: en 61000-4-4 level 3 10v/m burst: en 61000-4-5 level 4 4kv surge: en 61000-4-5 level 3 3kv conducted rf: en 61000-4-6 level 3 10v electromagn. compatibility (emc) acc. to en 500081-2, radiated noise en 55011 class b class b class b class b class b input current harmonics no limitation degree of protection terminals ip20 ip20 ip20 ip20 ip20 degree of protection enclosure ip50 ip30 ip50 ip30 ip50 protection class 1 1 1 1 1 general data efficiency approx. 84% approx. 82-84% approx. 83-86% approx. 82-86% approx. 83-86% (90-260vac) (102-260vac) (90-260vac) (140-260vac) status indication green led, power ok operating temperature 0??+55? storage temperature -25? ?+75? terminals screw terminals, 2 x 14 awg (2 x 2.5mm 2 ) weight approx. 0.22kg (0.49 lb) dimensions (w x h x d), mm 45 x 78 x 100 description cp-24/0.5 cp-24/1.0 cp-24/1.5 cp-24/2.0 cp-24/2.0 adj residual ripple / noise max.100mvss max.300mvss max.100mvss deviation of ouput with input change max. ?.5% max. ?.1% max. ?.5% max. ?.2% max. ?.5% deviaton of output with static load change max. ?.5% dev. of output with static load change 10 - 90% max. 5% short circuit protection overcurrent switch off with automatic restart overload protection overtemperature and overcurrent switch off reset after thermal overload disconnection of ac power input min. 30s standards, tests electrical safey standards en 50178 (vde 0160) / ul508 / csa 22.2 galvanic isolation reliable isolation acc. to iec 664-1, din vde 0106-101 voltage withstand input <-> output 2.5kvac, 3kvac type test clearance and creepage distances overvoltage category 2, pollution degree 2 electromagnetic compatibility (emc-tests) esd: en 61000-4-2 level 3 6/8kv acc. to en 50082-2 rf field: en 61000-4-4 level 3 10v/m burst: en 61000-4-5 level 4 4kv surge: en 61000-4-5 level 3 3kv conducted rf: en 61000-4-6 level 3 10v electromagn. compatibility (emc) acc. to en 500081-2, radiated noise en 55011 class b class b class b class b class b input current harmonics no limitation degree of protection terminals ip20 ip20 ip20 ip20 ip20 degree of protection enclosure ip50 ip50 ip30 ip20 ip30 protection class 1 1 1 1 1 general data efficiency approx. 84% approx. 82-84% approx. 83-86% approx. 82-86% approx. 83-86% (90-260vac) (102-260vac) (90-260vac) (140-260vac) status indication green led, power ok operating temperature 0? ?+55? storage temperature -25? ?+75? terminals screw terminals, 2 x 14awg (2.5mm 2 ) dimensions (w x h x d), mm 22.5 x 78 x 100 45 x 78 x 100 45 x 78 x 100 45 x 78 x 120 45 x 78 x 120
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 79 power supplies cp range t echnical data description cp-24/4.2 cp-24/5.0 cp-24/5.0 adj cp-48/0.7 cp-24/10 adj cp-24/20 adj residual ripple / noise max.200mvss max.300mvss max.50mvss max.100mvss deviation of output with input change max.?.05% max.?.5% max.?.2% deviation of output with static load change max.5% max.?.3 (?.5% parrallel operation) short circuit protection overcurrent switch off with automatic restart overload protection overtemperature and overcurrent switch off overcurrent limiting reset after thermal overload disconnection of acpower input min. 30s overvoltage protection triggerpoint at typ. 140% nom. output voltage parallel operation (option) up to 5 modules (must be enabled by internal jumper) standards, tests electrical safety standards en 50178 (vde 0160) en 50178 (vde 0160) / ul 508/ csa 22.2 en 9060 / ul 508 / csa 22.2 gakvanic isolation en 60950 iec 664-1 din/ en 60950 din/ en 60950 reliable isolation acc. to din/vde 0106-101 vde 0106-101 vde 0106-101 voltage withstand input<->output 1.5kvac, 3kvactype test 2.5kvac, 3kvactype test 3kvac type test clearance and creepage distances overvoltage category 3, overvoltage category 2, pollution degree 2 pollution degree 2 electromagn. comp. (emc tests) to en 50082-2 esd: en 61000-4-2 level 3 6/8kv en 61000-4-2 level 3 6/8kv rf field: en 61000-4-3 level 3 10v/m en 61000-4-3 level 3 10v/m burst: en 61000-4-4 level 3 2kv (cp-48/0.7 4kv) en 61000-4-4 level 3 4kv surge: en 61000-4-5 2kv (cp-48/0.7 3kv) en 61000-4-5 level 4 2/4kv conducted rf: en 61000-4-6 level 3 10v en 61000-4-6 level 3 10v input current harmonics no limitation degree of protection terminals ip20 ip20 ip20 ip20 ip20 ip20 degree of protection enclosure ip20 ip20 ip20 ip30 ip20 ip20 protection class 1 1 1 1 1 1 general data efficiency approx. 77-85% approx. 77-85% approx. 77-85% approx. 83-85% typ.90% typ. 88% (90-260vac) (90-260vac) (90-260vac) (90-260vac) (230vac) (230vac) status indication green led, power ok operating temperature 0? ?+55? -25? ?+70? storage temperature -25? ?+75? -25? ?+85? screw terminals 2x14 awg (2 x 2.5mm 2 ) 14awg (2.5mm 2 ) dimensions ( w x h x d), mm 90 x 78 x 120 45 x 78 x 100 100 x 125 x 125 220 x 125 x 125 mounting hints normal position: horizontal onto din-rail spacing to other modules left 1cm, vertical distances 5 cm both sides min. 5cm, vertical distances min. 8 cm
www.abb.com/lowvoltage email marketing.info@gb.abb.com telephone 02476 368551 facsimile 02476 368401 abb limited 2/ 80 power supplies cp range t echnical data description cp-l5/1.0 cp-l12/0.5 cp-l15/0.5 cp-l24/0.25 cp-l?2/0.5 cp-l12/1.0 cp-l15/1.0 cp-l24/0.75 cp-l?5/0.5 residual ripple / noise ?1% short circuit protection overcurrent switch off with automatic restart overload protection overtemperature and overcurrent switch off reset after thermal overload automatic after cooling standards, tests electrical safety standards en 50178 (vde 0160) galvanic isolation reliable isolation en 60950 voltage withstand input<->output 4kvac, 4vac test clearance and creepage distances overvoltage category iii pollution degree 2 electromagn. compatibility (emc-test) esd: en61000-4-2 level 3 (6/8kv) rf fields en61000-4-3 level 3 (10v/m) burst: en61000-4-4 level 3 (2kv) surge: en61000-4-5 level 3 (2kv) conducted rf: en61000-4-6 level 3 (10v) input current harmonics no limiting degree of protection terminals: ip20 enlcosures: ip20 protection class: 2 with external product protection general data status indication green led operating temperature -20 ?+50? storage temperature -40 ?+80? terminals screw terminals 14awg (2.5mm 2 ) dimensions (w x h x d) 0.25a 100 x 104 x 79mm dimensions (w x h x d) 0.25a 100 x 104 x 79mm 135 x 104 x 79mm dimensions (w x h x d) 0.25a 135 x 104 x 79mm dimensions (w x h x d) 0.25a 100 x 104 x 79mm mounting hints normal position: horizontal onto din rail, spacing to other modules upper 100mm, lower 50mm, sides 20mm


▲Up To Search▲   

 
Price & Availability of 1TXD00001C0201-2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X